Products

Series 3000 Cooling Tower

TRUSTED RELIABILITY AND HIGHEST EFFICIENCY

The Series 3000 Cooling Tower leads the industry with the highest efficiency and trusted reliability from BAC. Maintenance is also easiest with an open interior that allows for easiest access to all major components and the optional ENDURADRIVE® Fan System that requires virtually no maintenance for unmatched peace-of-mind. Extreme Efficiency (XE) models further reduce energy and operating costs.

  • Thermal Capacity: 171 – 1,446 tons1
  • Flow Rate: Up to 4,500 USGPM1
  • Crossflow // Axial Fan // Induced Draft

Benefits

Easiest Installation

PRE-ASSEMBLED PLATFORMS AND LADDERS

  • Reduce on-site labor requirements and ensure on-time commissioning with factory pre-assembled external platform and ladder options
  • Ensure proper fit for any application with flexible inlet/outlet piping connection locations
  • For field assembly, knockdown units are available
  • Reduce installation costs by eliminating overhead piping and piping support requirements with the optional EASY CONNECT® Piping Arrangement
  • Optional basinless construction is ideal for installations that use a common sump for multiple tower cells

Lowest Maintenance Costs

FASTEST ACCESS TO KEY COMPONENTS

  • Easiest access to the cold water basin, hot water basin, and the drive system with the crossflow design, large access doors, and an optional internal walkway
  • Fast inspection of the spray water distribution system while the unit is in operation
  • Virtually eliminate maintenance with the optional ENDURADRIVE® Fan System

Lowest Energy Usage

UP TO 40% MORE ENERGY EFFICIENT WITH XE MODELS*

  • Extremely efficient XE Models are at least two times more energy efficient than the minimum requirements established in ASHRAE Standard 90.1
  • XE models help to contribute to Energy and Atmosphere LEED® Credits (EAc1)
  • Average payback of less than two years with BAC’s enhanced selections which include user-defined life-cycle cost inputs based on energy savings and minimum payback

*Compared to standard cooling towers.

Lowest Maintenance Increased Layout Flexibility

MINIMIZE FOOTPRINT

  • For large projects, minimize space needed by fitting multiple units together
  • Installations can be easily expanded with additional cooling tower cells
  • Variety of options to meet layout requirements, including a range of structural steel spacings and a velocity recovery stack for additional cooling

OUR CLIENTS

[logocarousel id="3023"]